1 | 1 | Giulio Di Anastasio | h1. Portable Ultrasonic Flow Meter |
---|---|---|---|
2 | 1 | Giulio Di Anastasio | |
3 | 1 | Giulio Di Anastasio | Flow meter – for checking the flow of water in pipe |
4 | 1 | Giulio Di Anastasio | |
5 | 1 | Giulio Di Anastasio | CSR bought ultrasonic flow meter from Chennai and the company (company name? )trained Bala and Vijai(CSR) on how to set it up. |
6 | 1 | Giulio Di Anastasio | we tested in the west water system pump in csr. then we test in many more place . |
7 | 1 | Giulio Di Anastasio | ami, aurodam and buddha garden borewell pumps . we got request from the water service |
8 | 1 | Giulio Di Anastasio | Cross check they flow meters . |
9 | 1 | Giulio Di Anastasio | so before that we want to know how our meter works. |
10 | 1 | Giulio Di Anastasio | so we tested in our tank . the pump pumping from our sump tank so the flow will be stranded. when you pump in the bore well the flow goes up and down. |
11 | 1 | Giulio Di Anastasio | we tested two times in 15 minutes.and one time 30 minutes,so we got variation between this three. |
12 | 1 | Giulio Di Anastasio | we find 1,5 % error but the flow meret they said 1 % error only. |
13 | 1 | Giulio Di Anastasio | we cross checked the flow meter of the water service we find some error in they meter also. |
14 | 1 | Giulio Di Anastasio | we tried they bore well flowmeter and they sump tank flow meter also.and we find some error also in they meters. |
15 | 1 | Giulio Di Anastasio | then we find some error in (AVWS) meter also. |
16 | 1 | Giulio Di Anastasio | It is used to check the flow of water in pipe |
17 | 1 | Giulio Di Anastasio | tools used |
18 | 1 | Giulio Di Anastasio | First the outer diameter of the pipe has to be entered in the device. It is measured using Vernier caliper |
19 | 1 | Giulio Di Anastasio | Then the thickness of the pipe is set which is also measured using vernier |
20 | 1 | Giulio Di Anastasio | Also the device asks for the material of the pipe. If the pipe material is know it can be set and if it not know then there is an option which is other (mostly PVC, HDPE, and iron) |
21 | 1 | Giulio Di Anastasio | After entering these details the device gives the spacing for the sensors. There are 2 sensors up and down which has to be fixed accordingly |
22 | 1 | Giulio Di Anastasio | When the sensors are fixed the motor is turned on and the sensors send reading to the display device |